Fire Rated Loft Hatch Fitting and User Guide


Installation Advice

  • The product is designed to fit between 38mm thick trussed rafters or ceiling joists spaced at 600mm centres which provide a clear joist opening width of 562mm
  • If the roof design does not provide this joist opening width, a suitable opening must be formed Trimmers must be installed across the ends of the frame. These must be spaced to give a clear opening length of 726mm
  • The frame fixes with 16 screws.
  • Fit the loft access door after the ceiling has been plaster boarded and skimmed
  • The frame must be a good fit into the trimmed opening. Never try to force it into an opening that is too small. If the opening is too large use packers to ensure a good fit

Installation Instructions for Loft Hatches

  1. Trim out a suitable opening 562 wide x 726mm long.

  2. no 1 loft hatch instructions

  3. Fit a layer of 10mm plasterboard 95mm up the edge of the joist which will now leave an opening of 706mm long x 542mm wide.

  4. no 2 loft hatch instructions

  5. The ceiling should be finished and painted before installation. Offer up the frame and have the door open ensuring it sits square and flush with your ceiling. Use 50mm long woodscrews to secure the frame through the 16 no. pre punched holes. Lastly, seal around the join between the frame and your ceiling using a fire retardant mastic.

  6. no 3 loft hatch instructions

Operating Instructions for Loft Hatches

TO OPEN AND CLOSE

  1. Turn the catch 90 degrees to open or close the door using the T bar provided.


  2. no 4 loft hatch instructions


*All prices include VAT except Industrial Products & these are clearly marked